Availability: | |
---|---|
Quantity: | |
● Using water as refrigerant
Energy-saving corrosion resistant water-cooled air conditioner use water as refrigerant, replacing the fluorine-containing refrigerant in traditional air conditioners. Fluorine-containing refrigerants are flammable and explosive substances. Once fluorine-containing refrigerants leak, it is very dangerous. The use of water-cooled air conditioners avoids the risk of refrigerant leakage.
● Efficient
Energy-saving water-cooled air conditioner uses water to transfer heat, which is more efficient than air. This is mainly because water has a higher heat capacity and thermal conductivity compared to air. Consequently, water-cooled air conditioner for oxygen chamber can cool spaces more efficiently, thus consuming less energy.
● Safety
Water, as an ideal refrigerant, makes water-cooled chillers a safer alternative than those using fluorinated refrigerants. This ensures the safe of users in the hyperbaric oxygen chamber.
Detailed Parameter
Product name | Water-cooled Heating and Cooling Air Conditioner |
Water-cooled model | JHC05AW-HO-O |
Indoor Unit Dimensions | 440x190x165mm |
Outdoor Unit Dimensions | 533x374x288mm |
Cooling Water Temp. Range | 8~28℃ |
Operating Temperature Range | 15~42℃ |
Rated Cooling Power | 660W |
Power Supply Characteristics | 220-240V/50Hz |
Certificate | FCC CE |
Application Scenario
Water-cooled air conditioners are used in hyperbaric oxygen chambers to keep the air circulating and the temperature cool. This allows users to enjoy the hyperbaric oxygen therapy process more, increase relaxation, and feel comfortable.
Instructions For Use
① First connect the unit's water inlet/outlet pipes to the corresponding water inlet/outlet pipes of the indoor unit, and note that the connected water pipes need to correspond;
② Water filling I: Unplug the "water inlet" and "exhaust port" plugs on the back of the unit, and inject clean water from the "water inlet" until it is full (about 1000 ml).
③ Water filling II: Power on, and long press the "" and "
" button on the controller at the same time to enter the "water filling" mode. Continue to pour water from the "water filling port" until it is full.
④ Stop water filling and put the plug back. Exit the unit water filling mode (same as entering), long press "" and "
";
⑤ Power on/off: press the power on/off button "".
⑥ The controller can set the water outlet temperature, which is used to indirectly reflect the internal temperature of the oxygen chamber. The factory default is 9℃. You can set other temperatures by yourself, and the temperature setting range is 8~28℃. Press the "
" button.
⑦ Other button instructions: Press the "" button to check the unit operating parameters. Under normal circumstances, the user does not need to check. If this button is pressed, press "
" to return. "
" is the return button.
FAQ
Q: Is the water-cooled air conditioner safe?
A: Water-cooled air conditioners use water as refrigerant. Compared with fluorine-containing refrigerants, water is very safe and harmless. And it will not pollute the environment.
Q: Is the water-cooled air conditioner reliable?
A: The service life of water-cooled air conditioners is longer than that of ordinary air conditioners. Even if damage occurs, it is easier to repair and the maintenance cost is relatively low.
Q: What is the guarantee for our products?
A: Our products meet European standards and come with relevant certificates. At the same time, we provide a one-year warranty.
● Using water as refrigerant
Energy-saving corrosion resistant water-cooled air conditioner use water as refrigerant, replacing the fluorine-containing refrigerant in traditional air conditioners. Fluorine-containing refrigerants are flammable and explosive substances. Once fluorine-containing refrigerants leak, it is very dangerous. The use of water-cooled air conditioners avoids the risk of refrigerant leakage.
● Efficient
Energy-saving water-cooled air conditioner uses water to transfer heat, which is more efficient than air. This is mainly because water has a higher heat capacity and thermal conductivity compared to air. Consequently, water-cooled air conditioner for oxygen chamber can cool spaces more efficiently, thus consuming less energy.
● Safety
Water, as an ideal refrigerant, makes water-cooled chillers a safer alternative than those using fluorinated refrigerants. This ensures the safe of users in the hyperbaric oxygen chamber.
Detailed Parameter
Product name | Water-cooled Heating and Cooling Air Conditioner |
Water-cooled model | JHC05AW-HO-O |
Indoor Unit Dimensions | 440x190x165mm |
Outdoor Unit Dimensions | 533x374x288mm |
Cooling Water Temp. Range | 8~28℃ |
Operating Temperature Range | 15~42℃ |
Rated Cooling Power | 660W |
Power Supply Characteristics | 220-240V/50Hz |
Certificate | FCC CE |
Application Scenario
Water-cooled air conditioners are used in hyperbaric oxygen chambers to keep the air circulating and the temperature cool. This allows users to enjoy the hyperbaric oxygen therapy process more, increase relaxation, and feel comfortable.
Instructions For Use
① First connect the unit's water inlet/outlet pipes to the corresponding water inlet/outlet pipes of the indoor unit, and note that the connected water pipes need to correspond;
② Water filling I: Unplug the "water inlet" and "exhaust port" plugs on the back of the unit, and inject clean water from the "water inlet" until it is full (about 1000 ml).
③ Water filling II: Power on, and long press the "" and "
" button on the controller at the same time to enter the "water filling" mode. Continue to pour water from the "water filling port" until it is full.
④ Stop water filling and put the plug back. Exit the unit water filling mode (same as entering), long press "" and "
";
⑤ Power on/off: press the power on/off button "".
⑥ The controller can set the water outlet temperature, which is used to indirectly reflect the internal temperature of the oxygen chamber. The factory default is 9℃. You can set other temperatures by yourself, and the temperature setting range is 8~28℃. Press the "
" button.
⑦ Other button instructions: Press the "" button to check the unit operating parameters. Under normal circumstances, the user does not need to check. If this button is pressed, press "
" to return. "
" is the return button.
FAQ
Q: Is the water-cooled air conditioner safe?
A: Water-cooled air conditioners use water as refrigerant. Compared with fluorine-containing refrigerants, water is very safe and harmless. And it will not pollute the environment.
Q: Is the water-cooled air conditioner reliable?
A: The service life of water-cooled air conditioners is longer than that of ordinary air conditioners. Even if damage occurs, it is easier to repair and the maintenance cost is relatively low.
Q: What is the guarantee for our products?
A: Our products meet European standards and come with relevant certificates. At the same time, we provide a one-year warranty.